Car Questions

2017 F250 Auto Rege...
 
Notifications
Clear all

2017 F250 Auto Regen not happening

  

0
Topic starter

I have 2017 Ford F250 6.7L not going into auto regen.  The message center was indicating full and know indicates overloaded with an additional message telling me to drive to clean.  I have drove a 3 hr trip on the interstate with a trailer, but still no luck.  I have forscan and have attempted to do a manual regen but I receive an error message every time saying the parameters are not met.

What actually activates the auto regen to start (sensor)?


2 Answers
1

I think most DPFs use a pressure sensor, which can go bad; let’s hope it’s that, since it’s not an expensive fix.  But your problem could also be the filter itself or the computer.  A regular scan tool usually won’t figure it out.

Unless you can verify that exhaust/emissions components are still covered by your warranty (probably not) I would not take it to a dealer, because they are liable to send you right to replacing the DPF assembly ($5000+).  Go to an independent shop that does a lot of 6.7 powerstrokes.


Thanks. I will work with a diesel shop...can't get into the dealer anyway.


0

Any codes?


No codes. Just the message screen.


Share: