Notifications
Clear all
0
27/07/2023 4:42 pm
Topic starter
- Ac compressor went out had it replaced but ac still doesn’t blow like before and rear vents blow hot air.
- it blows cool but not strong like it did before. Had the sensor and condenser changed still the same problem
1 Answer
0
27/07/2023 5:34 pm
Had the sensor and condenser changed still the same problem
The condenser should have been replaced at the same time as the compressor, along with the expansion valve and the drier with the rest of the system being flushed out. If this was not done there is probably still contamination in your AC system from the failed compressor.
Was the correct amount of refrigerant by weight installed? What are your high and low system pressures?